OSHA SearchOSHA records by employer

Prime 1 Flooring Inc.: OSHA inspections and violations

Brooklyn, New York · Flooring Contractors · NAICS 238330

1inspections
4citation items
$7,179current penalties
Jul 28, 2021last inspection

Prime 1 Flooring Inc. has one OSHA inspection on record in New York.

OSHA opened it on Jul 28, 2021 as a planned inspection, in Brooklyn, and the case has not closed yet.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $13,053 in penalties. After settlements and reviews the total is $7,179, down 45%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Prime 1 Flooring Inc. averages $7,179 over 1 cited inspection in that time.

Prime 1 Flooring Inc.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Prime 1 Flooring Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345446611 OPENED JUL 28, 2021Open

Planned · Complete · Safety · 2 employees at the site · Open

3415 Farragut Rd, Brooklyn, NY 11210 · Flooring Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$3,108$1,700Jan 25, 2022Final
Citation 1, item 2
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$4,351$2,479Jan 25, 2022Final
Citation 1, item 3
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Serious$2,486$1,300Jan 25, 2022Final
Citation 1, item 4
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$3,108$1,700Jan 25, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(f)

(F) Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.

29 CFR 1926.416 · Electrical safety in construction

Other flooring contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.