Inspection 346883457 OPENED AUG 3, 2023Closed
15951 Little Axe Dr., Norman, OK 73026 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Prime Electric Company, Inc. has 18 OSHA inspections on record in Oklahoma, the first in 1985.
OSHA's last visit started on Aug 3, 2023 as a planned inspection, in Norman.
Across those inspections OSHA issued 8 citation items: 2 serious and 6 other-than-serious.
OSHA proposed $18,108 in penalties. After settlements and reviews the total is $4,527, down 75%.
Most often, OSHA cited 1926.50, medical services and first aid (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Prime Electric Company, Inc. averages $4,527 over 1 cited inspection in that time.
Prime Electric Company, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
The Wage and Hour Division has 1 case on it since 2015, with $0 in back wages owed to workers.
Oklahoma · latest 90 days of OSHA records
54employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oklahoma
Checking a subcontractor, a client or your own company? Watch Prime Electric Company, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company15951 Little Axe Dr., Norman, OK 73026 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
915 Classen Blvd., Norman, OK 73071 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2301 Nw 145th St., Oklahoma City, OK 73134 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2220 W. Iowa, Chickasha, OK 73018 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Apr 3, 2018: Employee is burned in electric arc flash
At 2:00 p.m. on April 3, 2018, Employee #1, employed by an electrical services company, was removing a temporary electrical power wire from a facility's power room. An arc flash occurred, and Employee #1 was burned. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for first and fourth degree burns to his stomach, chest, neck, face, arms, and hands.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.95(a) · Criteria for personal protective equipment |
Serious | $9,054 | $4,527 | Oct 1, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.416(a)(1) · Electrical safety in construction |
Serious | $9,054 | $0 | Oct 1, 2018 | Final |
2300 N. Pennsylvania, Edmond, OK 73083 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2600 N.e 63rd, Oklahoma City, OK 73111 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
830 Van Vleet Oval, Norman, OK 73069 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 N. University-uco Stadium, Edmond, OK 73083 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Boone Pickens Stadium - Osu Campus, Stillwater, OK 74076 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5300 E. Covell Rd., Edmond, OK 73083 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
101 E. Constellation, Norman, OK 73019 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1271 W. Covell, Edmond, OK 73034 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
S.w. Bryant & Danforth Road, Edmond, OK 73034 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
(osu) Animal Care Facility, Osu Campus, Stillwater, OK 74074 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.50(d)(1) · Medical services and first aid |
Other-than-serious | $0 | $0 | Aug 16, 1994 | Closed |
1920 Alameda, Norman, OK 73071 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.50(c) · Medical services and first aid |
Other-than-serious | $0 | $0 | Feb 10, 1994 | Closed |
| Citation 1, item 2 29 CFR 1926.50(f) · Medical services and first aid |
Other-than-serious | $0 | $0 | Feb 10, 1994 | Closed |
| Citation 1, item 3 29 CFR 1926.150(e)(2) · Fire protection |
Other-than-serious | $0 | $0 | Feb 10, 1994 | Closed |
4401 W. Memorial Rd., Oklahoma City, OK 73120 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Jul 29, 1987 | Closed |
Ueph-bldg 5909, Tinker Air Force Base, OK 73145 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6000 East Reno, Midwest City, OK 73110 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.400(h)(1) · Introduction |
Other-than-serious | $0 | $0 | Jul 26, 1985 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Edmond site logged 1 recordable injury or illness among about 46 workers: 2.2 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 9 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Prime Electric Company, Inc. Edmond · 2023 | 46 | 1 | 1 | 2.2 | 1.8 |
| Prime Electric Edmond · 2019 | 58 | 1 | 1 | 2.0 | 1.8 |
Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Apr 3, 2018, Chickasha: Hospitalization · electrical burns, unspecified · nonclassifiable
An employee was disconnecting 440-volt, 3-phase temporary power when an arc flash occurred. The employee suffered arc flash burns over 18% of the body.
Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
| Period reviewed | Violations | Workers owed | Back wages | Penalties |
|---|---|---|---|---|
| Jun 7, 2019 to Mar 31, 2020 Edmond | 43 | 0 | $0 | $0 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.150(e)(2)
(2) The alarm code and reporting instructions shall be conspicuously posted at phones and at employee entrances.
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
29 CFR 1926.416(a)(1)
(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.
Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.