Inspection 347583072 OPENED JUN 26, 2024Closed
220 Frederick Street, Mount Airy, NC 27030 · Industrial Launderers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Mount Airy, North Carolina · Industrial Launderers · NAICS 812332
OSHA has inspected Prime Kleen Commerical Laundry Inc 2 times in North Carolina since 2023.
The latest one began on Jun 26, 2024 to follow up on an earlier case, in Mount Airy.
Those inspections ended with 3 citation items: 2 serious and 1 other-than-serious.
Penalties were first proposed at $8,000 and now stand at $6,000, 25% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 2 items under 1910.147.
How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Prime Kleen Commerical Laundry Inc averages $6,000 (1 cited inspection).
North Carolina · latest 90 days of OSHA records
231employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Prime Kleen Commerical Laundry Inc and get notified the morning OSHA posts a new citation for it.
Watch this company220 Frederick Street, Mount Airy, NC 27030 · Industrial Launderers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
220 Frederick Street, Mount Airy, NC 27030 · Industrial Launderers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $4,000 | $3,000 | Feb 20, 2024 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout |
Serious | $4,000 | $3,000 | Feb 20, 2024 | Final |
| Citation 2, item 1 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Feb 20, 2024 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(7)(i)(a)
(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.
29 CFR 1910.303(b)(7)(i)
(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.