Inspection 342543790 OPENED JUL 13, 2017Closed
125 E 70th Street, New York, NY 10021 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2013, OSHA inspectors have visited Primo Remodeling Inc in New York 4 times.
The most recent inspection opened on Jul 13, 2017 to follow up on an earlier case, in New York.
In all, OSHA issued 3 citation items: 3 serious.
The proposed penalties came to $12,140; today they stand at $8,605, 29% less.
The rule cited most here is 1926.304 (woodworking tools), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Primo Remodeling Inc averages $7,605 across 1 cited inspection.
New York · latest 90 days of OSHA records
362employers cited
19 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Primo Remodeling Inc and get notified the morning OSHA posts a new citation for it.
Watch this company125 E 70th Street, New York, NY 10021 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
125 E 70th Street, New York, NY 10021 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.304(i)(1) · Woodworking tools |
Serious | $5,070 | $3,802 | May 8, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.1052(c)(1) · Stairways in construction |
Serious | $5,070 | $3,802 | May 8, 2017 | Final |
122 East 78th St, New York, NY 10075 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
122 East 78th St, New York, NY 10075 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.304(h)(1) · Woodworking tools |
Serious | $2,000 | $1,000 | May 1, 2013 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1052(c)(1)
(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:
29 CFR 1926.304(h)(1)
(h) Hand-fed crosscut table saws. (1) Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws.
29 CFR 1926.304(i)(1)
(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.