OSHA SearchOSHA records by employer

Pro-Pac Interiors Inc: OSHA inspections and violations

Wasilla, Alaska · Framing Contractors · NAICS 238130

2inspections
3citation items
$1,785current penalties
Dec 8, 2016last inspection

OSHA has inspected Pro-Pac Interiors Inc 2 times in Alaska since 2015.

The latest one began on Dec 8, 2016 on a referral, in Wasilla.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $2,325 and now stand at $1,785, 23% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Pro-Pac Interiors Inc averages $892 (2 cited inspections).

Pro-Pac Interiors Inc: OSHA citation items per year, 2015 to 2016
Citation items per year, by inspection date.

Alaska · latest 90 days of OSHA records

37employers cited

Get notified the morning OSHA posts each new citation in Alaska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alaska

Checking a subcontractor, a client or your own company? Watch Pro-Pac Interiors Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342128311 OPENED DEC 8, 2016Closed

Referral · Partial · Safety · 4 employees at the site · Closed May 12, 2017

L1 B2 Cogland Estates, Wasilla, AK 99654 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$1,000$700Mar 7, 2017Final
Citation 1, item 3
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$800$560Mar 7, 2017Final

Inspection 340682335 OPENED MAY 27, 2015Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Mar 16, 2016

Corner Of West Marble Way And S. Lance B Circle, Wasilla, AK 99687 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$525$525Aug 6, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(c)(2)(iv)

(iv) Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(14)

(14) Wall openings. Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, shall be protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system.

Other framing contractors employers in Alaska

Alert subscribers get notified of each newly cited employer in Alaska the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.