OSHA SearchOSHA records by employer

Pro Service Construction, LLC: OSHA inspections and violations

Frenchtown, New Jersey · Siding Contractors · NAICS 238170

1inspections
2citation items
$5,328current penalties
Aug 3, 2021last inspection

OSHA inspectors have visited Pro Service Construction, LLC in New Jersey one time.

It opened on Aug 3, 2021 after a complaint, in Frenchtown.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $8,192; today they stand at $5,328, 35% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pro Service Construction, LLC averages $5,328 across 1 cited inspection.

Pro Service Construction, LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

264employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Pro Service Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345455844 OPENED AUG 3, 2021Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Dec 29, 2021

1 Eighth Street - Country Classics At Frenchtown, Frenchtown, NJ 08825 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,096$2,664Aug 16, 2021Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,096$2,664Aug 16, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.