OSHA has inspected Pro-Spec Painting Inc. 5 times in New Jersey since 1989.

The latest one began on Jul 23, 2016 on a referral, in Old Bridge.

Those inspections ended with 25 citation items: 23 serious and 2 other-than-serious.

Penalties were first proposed at $52,643 and now stand at $36,903, 30% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 10 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Pro-Spec Painting Inc. averages $18,266 (2 cited inspections).

Pro-Spec Painting Inc.: OSHA citation items per year, 1989 to 2016
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

276employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Pro-Spec Painting Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341661767 OPENED JUL 23, 2016Closed

Referral · Partial · Safety · 7 employees at the site · Closed Apr 17, 2019

Old Waterworks Road Runyon Water Treatment Facility, Old Bridge, NJ 08857 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,897$2,897Jan 20, 2017Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,622$3,622Jan 20, 2017Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$5,070$5,070Jan 20, 2017Final

Inspection 341512945 OPENED MAY 26, 2016Closed

Referral · Partial · Health · 50 employees at the site · Closed Jun 17, 2019

179 Hillcrest Avenue, Morristown, NJ 07960 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$6,236$6,236Dec 9, 2016Final
Citation 1, item 1b
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Dec 9, 2016Final
Citation 1, item 1c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Dec 9, 2016Final
Citation 1, item 1d
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Dec 9, 2016Final
Citation 1, item 2
29 CFR 1926.52(d)(1) · Occupational noise exposure
Serious$6,236$6,236Dec 9, 2016Final
Citation 1, item 3
29 CFR 1926.1203(d) · Confined Spaces in Construction: general requirements
Serious$6,236$6,236Dec 9, 2016Final
Citation 1, item 4
29 CFR 1926.1203(e)(2)(iii) · Confined Spaces in Construction: general requirements
Serious$6,236$6,236Dec 9, 2016Final

Inspection 310143631 OPENED OCT 26, 2006Closed

Complaint · Complete · Safety · 6 employees at the site · Closed Aug 20, 2010

4 Aurora Drive, Cranbury, NJ 08512 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$750$0Apr 25, 2007Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 3
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 4
29 CFR 1926.451(c)(1)(i) · Scaffolds, general requirements
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 5
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 6
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 7
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 8
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 9
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 10
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Serious$1,500$10Apr 25, 2007Final
Citation 1, item 11
29 CFR 1926.454(a) · Scaffold training
Serious$1,500$10Apr 25, 2007Final
Citation 2, item 1
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0Apr 25, 2007Final

Inspection 17801101 OPENED MAY 8, 1990Closed

Referral · Complete · Safety · 10 employees at the site · Closed May 16, 1990

A.e. Stone, P.o. Box 101 -dougherty Road, Pleasantville, NJ 08232 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 101504611 OPENED JUN 2, 1989Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 26, 1989

1819 Cedar Ave., Vineland, NJ 08360 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$120$90Aug 23, 1989Closed
Citation 1, item 2
29 CFR 1926.59(g)(1) · Hazard communication
Serious$120$90Aug 23, 1989Closed
Citation 1, item 3
29 CFR 1926.59(h) · Hazard communication
Serious$120$90Aug 23, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.52 · Occupational noise exposure

29 CFR 1926.59 · Hazard communication