OSHA SearchOSHA records by employer

Pro Tile and Vinyl: OSHA inspections and violations

Fort Belvoir, Virginia · Tile and Terrazzo Contractors · NAICS 238340

1inspections
3citation items
$1,194current penalties
Jan 16, 2019last inspection

Pro Tile and Vinyl has one OSHA inspection on record in Virginia.

OSHA opened it on Jan 16, 2019 as a planned inspection, in Fort Belvoir.

From that inspection OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $1,705 in penalties. After settlements and reviews the total is $1,194, down 30%.

Most often, OSHA cited 1926.404, ground-fault protection on job sites (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Pro Tile and Vinyl averages $1,194 over 1 cited inspection in that time.

Pro Tile and Vinyl: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Pro Tile and Vinyl and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343829115 OPENED JAN 16, 2019Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 6, 2019

Building 247, Fort Belvoir, VA 22060 · Tile and Terrazzo Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,705$1,194Mar 19, 2019Final
Citation 2, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Mar 19, 2019Final
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 19, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

Other tile and terrazzo contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.