Inspection 342152592 OPENED FEB 28, 2017Closed
1115 W Main St., Ada, OK 74820 · Support Activities for Animal Production · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2016, OSHA inspectors have visited Pro Walk Manufacturing Company Inc. in Oklahoma 2 times.
The most recent inspection opened on Feb 28, 2017 to follow up on an earlier case, in Ada.
In all, OSHA issued 3 citation items: 3 serious.
The penalties, $1,200 in total, stand where OSHA first set them.
The rule cited most here is 1910.305 (electrical wiring methods), 3 times.
Among farming, fishing and forestry employers, the typical cited inspection since 2015 ends with a $1,440 penalty. Pro Walk Manufacturing Company Inc. averages $1,200 across 1 cited inspection.
Oklahoma · latest 90 days of OSHA records
56employers cited
Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oklahoma
Checking a subcontractor, a client or your own company? Watch Pro Walk Manufacturing Company Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1115 W Main St., Ada, OK 74820 · Support Activities for Animal Production · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1115 W Main St., Ada, OK 74820 · Support Activities for Animal Production · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.305(b)(1)(i) · Electrical wiring methods |
Serious | $1,200 | $1,200 | Mar 25, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Mar 25, 2016 | Final |
| Citation 1, item 1c 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Mar 25, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.305(b)(1)(i)
(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. (i) Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.
29 CFR 1910.305(g)(1)(iv)(a)
(A) As a substitute for the fixed wiring of a structure;
29 CFR 1910.305(g)(2)(ii)
(ii) Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.