Inspection 342987211 OPENED FEB 27, 2018Closed
60 River Rd West, Berlin, MA 01503 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.102(a)(1) · Eye and face protection in construction |
Serious | $3,696 | $3,696 | May 2, 2018 | Final |
| Citation 1, item 2 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Serious | $2,217 | $2,217 | May 2, 2018 | Final |
| Citation 1, item 3 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $2,217 | $2,217 | May 2, 2018 | Final |
| Citation 1, item 4 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $5,174 | $5,174 | May 2, 2018 | Final |
| Citation 1, item 5 29 CFR 1926.452(w)(2) · Rules for each type of scaffold |
Serious | $4,434 | $4,434 | May 2, 2018 | Final |
| Citation 2, item 1 29 CFR 1903.19(c)(3) · Proving cited hazards were fixed |
Other-than-serious | $415 | $415 | Jul 31, 2018 | Final |
| Citation 2, item 2 29 CFR 1903.19(d)(1) · Proving cited hazards were fixed |
Other-than-serious | $415 | $415 | Jul 31, 2018 | Final |