OSHA SearchOSHA records by employer

Professional Builders: OSHA inspections and violations

Pittsburgh, Pennsylvania · Drywall and Insulation Contractors · NAICS 238310

1inspections
3citation items
$3,349current penalties
Apr 12, 2023last inspection

Professional Builders has one OSHA inspection on record in Pennsylvania.

OSHA opened it on Apr 12, 2023 as a planned inspection, in Pittsburgh.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $3,349 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Professional Builders averages $3,349 over 1 cited inspection in that time.

Professional Builders: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Professional Builders and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346628738 OPENED APR 12, 2023Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jan 5, 2026

7507 Mcknight Road, Pittsburgh, PA 15237 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,349$3,349May 19, 2023Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0May 19, 2023Final
Citation 1, item 1c
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0May 19, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.451(g)(4)(xv)

(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each upright shall be no more than 48 inches (1.3 m) apart.

Other drywall and insulation contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.