OSHA SearchOSHA records by employer

Professional Construction Management, Inc.: OSHA inspections and violations

Draper, Utah · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
3citation items
$2,025current penalties
Dec 22, 2016last inspection

OSHA has inspected Professional Construction Management, Inc. once in Utah.

The inspection began on Dec 22, 2016 as a planned inspection, in Draper.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $4,050 and now stand at $2,025, 50% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Professional Construction Management, Inc. averages $2,025 (1 cited inspection).

Professional Construction Management, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Professional Construction Management, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341990588 OPENED DEC 22, 2016Closed

Planned · Partial · Safety · 2 employees at the site · Closed Mar 31, 2017

12390 S 600 E, Draper, UT 84020 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(6) · Fall protection in construction
Serious$1,500$750Jan 25, 2017Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,500$750Jan 25, 2017Final
Citation 1, item 3
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$1,050$525Jan 25, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(6)

(6) Ramps, runways, and other walkways. Each employee on ramps, runways, and other walkways shall be protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.

Other new single-family housing construction (except for-sale builders) employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.