OSHA SearchOSHA records by employer

Professional Plumbing Service, Inc.: OSHA inspections and violations

Cedar Rapids, Iowa · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

2inspections
2citation items
$596current penalties
May 4, 2018last inspection

Since 2001, OSHA inspectors have visited Professional Plumbing Service, Inc. in Iowa 2 times.

The most recent inspection opened on May 4, 2018, in Cedar Rapids.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $1,491; today they stand at $596, 60% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Professional Plumbing Service, Inc. averages $446 across 1 cited inspection.

Professional Plumbing Service, Inc.: OSHA citation items per year, 2001 to 2018
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

59employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Professional Plumbing Service, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343140372 OPENED MAY 4, 2018Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Jun 13, 2018

442 5th Avenue Sw, Cedar Rapids, IA 52404 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$891$446May 23, 2018Final

Inspection 303742464 OPENED MAY 3, 2001Closed

Unprogrammed related · Complete · Safety · 15 employees at the site · Closed Dec 19, 2001

1037 74th Street N.e., Cedar Rapids, IA 52402 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$600$150Jun 13, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other plumbing, heating, and air-conditioning contractors employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.