Inspection 344558036 OPENED JAN 15, 2020Closed
41300 Coca Cola Dr, Belleville, MI 48111 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Belleville, Michigan · Industrial Machinery and Equipment Merchant Wholesalers · NAICS 423830
Professional Pump Inc has 3 OSHA inspections on record in Michigan, the first in 2012.
OSHA's last visit started on Jan 15, 2020 to follow up on an earlier case, in Belleville.
Across those inspections OSHA issued 13 citation items: 6 serious and 7 other-than-serious.
OSHA proposed $1,900 in penalties. After settlements and reviews the total is $1,060, down 44%.
Most often, OSHA cited 1910.147, lockout/tagout (3 items).
For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,425. Professional Pump Inc averages $500 over 1 cited inspection in that time.
Professional Pump Inc also files yearly injury logs with OSHA, summarized below.
Want to know if OSHA cites Professional Pump Inc again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company41300 Coca Cola Dr, Belleville, MI 48111 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2800 Plymouth Rd, Ann Arbor, MI 48109 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $500 | $500 | Nov 28, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.147(f)(2)(i) · Lockout/tagout |
Serious | $0 | $0 | Nov 28, 2018 | Final |
| Citation 1, item 1c 29 CFR 1910.147(f)(3)(ii)(d) · Lockout/tagout |
Serious | $0 | $0 | Nov 28, 2018 | Final |
41300 Coca Cola Dr, Belleville, MI 48111 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $500 | $200 | Mar 16, 2012 | Closed |
| Citation 1, item 2 | Serious | $400 | $160 | Mar 16, 2012 | Closed |
| Citation 1, item 3 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $500 | $200 | Mar 16, 2012 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Mar 16, 2012 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Mar 16, 2012 | Closed |
| Citation 2, item 3 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 16, 2012 | Closed |
| Citation 2, item 4 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 16, 2012 | Closed |
| Citation 2, item 5 | Other-than-serious | $0 | $0 | Mar 16, 2012 | Closed |
| Citation 2, item 6 | Other-than-serious | $0 | $0 | Mar 16, 2012 | Closed |
| Citation 2, item 7 29 CFR 1910.1200(f)(5) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 16, 2012 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Belleville site logged 0 recordable injuries or illnesses among about 31 workers: 0.0 per 100 full-time workers, against a median of 1.4 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Professional Pump Belleville · 2024 | 31 | 0 | 0 | 0.0 | 1.4 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(f)(5)
(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(f)(2)(i)
(2) Check the work area to ensure that all employees have been safely positioned or removed from the area.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.