Inspection 346603590 OPENED MAR 31, 2023Closed
176 12th St, Brooklyn, NY 11215 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Great Neck, New York · Residential Remodelers · NAICS 236118
OSHA has inspected Prosperity Construction NY, Inc. 2 times in New York since 2022.
The latest one began on Mar 31, 2023 as a planned inspection, in Brooklyn.
Those inspections ended with 5 citation items: 5 serious.
Penalties were first proposed at $12,432 and still stand at $12,432.
Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Prosperity Construction NY, Inc. averages $12,432 (1 cited inspection).
New York · latest 90 days of OSHA records
353employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Prosperity Construction NY, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company176 12th St, Brooklyn, NY 11215 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
88 Udall Dr., Great Neck, NY 11021 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $3,108 | $3,108 | Nov 10, 2022 | Final |
| Citation 1, item 2 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $3,108 | $3,108 | Nov 10, 2022 | Final |
| Citation 1, item 3 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $3,108 | $3,108 | Nov 10, 2022 | Final |
| Citation 1, item 4a 29 CFR 1926.454(a) · Scaffold training |
Serious | $3,108 | $3,108 | Nov 10, 2022 | Final |
| Citation 1, item 4b 29 CFR 1926.454(b) · Scaffold training |
Serious | $0 | $0 | Nov 10, 2022 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(f)(7)
(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.
29 CFR 1926.451(g)(1)(vii)
(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.