Inspection 341621902 OPENED JUL 13, 2016Closed
9401 Bay Area Blvd. Sutie 100, Pasadena, TX 77507 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $12,471 | $6,236 | Dec 30, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Other-than-serious | $12,471 | $6,236 | Dec 30, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $12,471 | $6,236 | Dec 30, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $9,799 | $4,900 | Dec 30, 2016 | Final |
| Citation 1, item 5 29 CFR 1910.304(b)(2)(iii) · Grounding and circuit protection |
Other-than-serious | $12,471 | $6,236 | Dec 30, 2016 | Final |