Prysmian Cables and Systems USA LLC: OSHA inspections and violations

Williamsport, Pennsylvania · Other Fabricated Wire Product Manufacturing · NAICS 332618

2inspections
1citation items
$16,550current penalties
Nov 26, 2025last inspection

Prysmian Cables and Systems USA LLC has 2 OSHA inspections on record in Pennsylvania, the first in 2025.

OSHA's last visit started on Nov 26, 2025 on a referral, in Williamsport.

Across those inspections OSHA issued 1 citation item: 1 serious.

OSHA proposed $16,550 in penalties and the amount has not been reduced.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Prysmian Cables and Systems USA LLC averages $16,550 over 1 cited inspection in that time.

Prysmian Cables and Systems USA LLC also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Prysmian Cables and Systems USA LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

274employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Prysmian Cables and Systems USA LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Prysmian Cables and Systems USA LLC at 4 sites in 4 states. Together they've had 11 inspections and $158,942 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 348615345 OPENED NOV 26, 2025Closed

Referral · Partial · Safety · 290 employees at the site · Closed Apr 22, 2026

409 Reighard Avenue, Williamsport, PA 17701 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348390022 OPENED JUL 22, 2025Closed

Referral · Partial · Safety · 278 employees at the site · Closed Jan 23, 2026

409 Reighard Avenue, Williamsport, PA 17701 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$16,550$16,550Sep 30, 2025Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Williamsport site logged 5 recordable injuries or illnesses among about 271 workers: 1.7 per 100 full-time workers, against a median of 1.5 for its industry. Those cases cost 330 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Prysmian Cables and Systems USA, LLC Williamsport
Williamsport · 2025
271 531.71.5
Prysmian Cables and Systems USA LLC
Williamsport · 2022
238 1043.82.9

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Nov 10, 2025, Williamsport: Amputation · amputations, avulsions, enucleations unspecified · other finger(s) n.e.c.

An employee was troubleshooting/performing maintenance on a wire strander machine. While working to fix the bobbin lock, the spring and ball bearing broke while the employee's left index finger was inside the thread hole. This caused the bobbin lock to come down onto the employee's finger, resulting in partial amputation.

Jul 15, 2025, Williamsport: Hospitalization · traumatic injuries or exposures unspecified · multiple body parts n.e.c.

An employee opened a service door for a spooler house draw bench and leaned inside to change a bobbin. The door then closed on her, striking and injuring her neck and knee. The employee was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.