OSHA SearchOSHA records by employer

Pulaski CSD Bus Garage: OSHA inspections and violations

Pulaski, New York · School and Employee Bus Transportation · NAICS 485410

5inspections
29citation items
$0current penalties
Apr 29, 2015last inspection

Since 2008, OSHA inspectors have visited Pulaski CSD Bus Garage in New York 5 times.

The most recent inspection opened on Apr 29, 2015 to follow up on an earlier case, in Pulaski.

In all, OSHA issued 29 citation items: 26 serious and 3 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.179 (overhead and gantry cranes), 5 times.

Among transportation and warehousing employers, the typical cited inspection since 2015 ends with a $2,416 penalty. Pulaski CSD Bus Garage averages $0 across 1 cited inspection.

Pulaski CSD Bus Garage: OSHA citation items per year, 2008 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Pulaski CSD Bus Garage and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340599463 OPENED APR 29, 2015Closed

Follow-up · Partial · Safety · Local government · 22 employees at the site · Closed Apr 29, 2015

4662 South Salina St, Pulaski, NY 13142 · Bus and Other Motor Vehicle Transit Systems · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340432954 OPENED FEB 27, 2015Closed

Planned · Complete · Safety · Local government · 22 employees at the site · Closed Apr 20, 2015

4662 South Salina St, Pulaski, NY 13142 · Bus and Other Motor Vehicle Transit Systems · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(b)(3) · Overhead and gantry cranes
Serious$0$0Mar 25, 2015Final
Citation 1, item 2
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Serious$0$0Mar 25, 2015Final
Citation 1, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Mar 25, 2015Final
Citation 1, item 4
29 CFR 1910.1200(f)(6) · Hazard communication
Serious$0$0Mar 25, 2015Final
Citation 1, item 5
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Mar 25, 2015Final
Citation 1, item 6
29 CFR 1910.212(b) · Machine guarding
Serious$0$0Mar 25, 2015Final
Citation 1, item 7
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 25, 2015Final
Citation 1, item 8
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Mar 25, 2015Final
Citation 2, item 1
29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment
Other-than-serious$0$0Mar 25, 2015Final
Citation 2, item 2
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Mar 25, 2015Final

Inspection 308527480 OPENED JUN 9, 2008Closed

Follow-up · Partial · Safety · Local government · 20 employees at the site · Closed Jun 9, 2008

4662 South Salina St., Pulaski, NY 13142 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308526581 OPENED MAR 4, 2008Closed

Monitoring · Partial · Safety · Local government · 20 employees at the site · Closed Mar 26, 2008

4662 South Salina St., Pulaski, NY 13142 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308526227 OPENED JAN 10, 2008Closed

Planned · Complete · Safety · Local government · 20 employees at the site · Closed Jun 9, 2008

4662 South Salina St., Pulaski, NY 13142 · School and Employee Bus Transportation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(c) · General requirements
Serious$0$0Jan 25, 2008Closed
Citation 1, item 2
29 CFR 1910.23(a)(2) · Guarding floor and wall openings and holes
Serious$0$0Jan 25, 2008Closed
Citation 1, item 3
29 CFR 1910.23(b)(1)(i) · Guarding floor and wall openings and holes
Serious$0$0Jan 25, 2008Closed
Citation 1, item 4
29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes
Serious$0$0Jan 25, 2008Closed
Citation 1, item 5
29 CFR 1910.36(b)(4) · Exit route design
Serious$0$0Jan 25, 2008Closed
Citation 1, item 6
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$0$0Jan 25, 2008Closed
Citation 1, item 7
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Jan 25, 2008Closed
Citation 1, item 8
29 CFR 1910.179(b)(3) · Overhead and gantry cranes
Serious$0$0Jan 25, 2008Closed
Citation 1, item 9
29 CFR 1910.179(h)(2)(v) · Overhead and gantry cranes
Serious$0$0Jan 25, 2008Closed
Citation 1, item 10
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$0$0Jan 25, 2008Closed
Citation 1, item 11
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$0$0Jan 25, 2008Closed
Citation 1, item 12
29 CFR 1910.212(b) · Machine guarding
Serious$0$0Jan 25, 2008Closed
Citation 1, item 13
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jan 25, 2008Closed
Citation 1, item 14
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$0$0Jan 25, 2008Closed
Citation 1, item 15
29 CFR 1910.305(b)(1)(iii) · Electrical wiring methods
Serious$0$0Jan 25, 2008Closed
Citation 1, item 16
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Jan 25, 2008Closed
Citation 1, item 17
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$0$0Jan 25, 2008Closed
Citation 1, item 18
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Jan 25, 2008Closed
Citation 2, item 1
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 25, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)

(6) Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes