OSHA SearchOSHA records by employer

Pulaski Roofers, Inc.: OSHA inspections and violations

Perry Hall, Maryland · Roofing Contractors · NAICS 238160

6inspections
12citation items
$6,972current penalties
Oct 27, 2023last inspection

Since 1995, OSHA inspectors have visited Pulaski Roofers, Inc. in Maryland 6 times.

The most recent inspection opened on Oct 27, 2023 as a planned inspection, in Baltimore.

In all, OSHA issued 12 citation items: 9 serious, 2 repeat and 1 other-than-serious.

The proposed penalties came to $14,723; today they stand at $6,972, 53% less.

The rule cited most here is 1926.501 (fall protection in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pulaski Roofers, Inc. averages $1,493 across 4 cited inspections.

1 inspection on this page followed a fatal incident.

Pulaski Roofers, Inc.: OSHA citation items per year, 1995 to 2023
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

35 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Pulaski Roofers, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347063794 OPENED OCT 27, 2023Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 21, 2024

333 Homeland Southway, Baltimore, MD 21212 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$375$270Dec 13, 2023Final
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$4,800$2,274Dec 13, 2023Final

Inspection 345421325 OPENED JUL 16, 2021Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 15, 2021

9405 Snyder Lane, Nottingham, MD 21236 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$312$225Aug 6, 2021Final
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$2,800$2,016Aug 6, 2021Final

Inspection 344276258 OPENED AUG 30, 2019Closed

Planned · Complete · Safety · 3 employees at the site · Closed Dec 11, 2019

4024 Klausmier Road, Perry Hall, MD 21128 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$312$180Oct 29, 2019Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$375$220Oct 29, 2019Final
Citation 2, item 1 Other-than-serious$0$0Oct 29, 2019Final

Inspection 342734258 OPENED OCT 27, 2017Closed

Planned · Complete · Safety · 4 employees at the site · Closed Mar 15, 2018

9404 Good Spring Drive, Perry Hall, MD 21128 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$875$551Jan 18, 2018Final
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Jan 18, 2018Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$437$236Jan 18, 2018Final

Inspection 303266019 OPENED DEC 7, 1999Closed

Accident · Complete · Safety · 2 employees at the site · Closed Apr 12, 2000

5441 Belair Road, Perry Hall, MD 21128 · OSHA's record · Phone and website on Google Maps

Incident on Dec 6, 1999 (fatal): Employee killed on excavation site

Employee #1 working on an excavation site was struck in a chest and killed by a motor vehicle.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 50702 C01 I
Serious$3,500$500Jan 28, 2000Closed

Inspection 119571578 OPENED JUL 3, 1995Closed

Accident · Partial · Health · 5 employees at the site · Closed Jul 31, 1996

6625 Kenwood Avenue, Baltimore, MD 21237 · OSHA's record · Phone and website on Google Maps

Incident on Jul 3, 1995: Electric shock - contact with overhead line thru hoist

An employee was moving a metal material hoist. The hoist consisted of four secti ons that were 35 feet long. The hoist contacted a 7600-volt-to-ground overhead p ower line, and the employee was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$937$500Aug 24, 1995Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.306 · Air receivers

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.