OSHA SearchOSHA records by employer

Pulte Homes: OSHA inspections and violations

Albuquerque, New Mexico · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

6inspections
3citation items
$2,100current penalties
Feb 2, 2018last inspection

Since 2004, OSHA inspectors have visited Pulte Homes in New Mexico 6 times.

The most recent inspection opened on Feb 2, 2018 on a referral, in Santa Fe.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $4,100; today they stand at $2,100, 49% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pulte Homes averages $500 across 1 cited inspection.

Pulte Homes: OSHA citation items per year, 2004 to 2018
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

35employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch Pulte Homes and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342931748 OPENED FEB 2, 2018Closed

Referral · Complete · Safety · 6 employees at the site · Closed Jun 11, 2018

4759 Lluvia Encantada, Santa Fe, NM 87508 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$500$500Apr 6, 2018Final

Inspection 342858461 OPENED JAN 3, 2018Closed

Referral · No inspection · Safety · Closed Jan 8, 2018

4746 Liuvia Encantada, Santa Fe, NM 87508 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309268597 OPENED AUG 9, 2005Closed

Referral · Complete · Safety · 12 employees at the site · Closed Feb 1, 2006

1109 Tokachi Dr, Albuquerque, NM 87105 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307130104 OPENED MAY 24, 2005Closed

Referral · Complete · Safety · 8 employees at the site · Closed Dec 20, 2005

Highline & Coliber, Los Lunas, NM 87031 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$2,000$0Aug 23, 2005Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,600$1,600Aug 23, 2005Final

Inspection 307126029 OPENED AUG 4, 2004Closed

Planned · Partial · Safety · 80 employees at the site · Closed Aug 24, 2004

6524 Avenida Seville, Albuquerque, NM 87114 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307125690 OPENED AUG 3, 2004Closed

Planned · Complete · Safety · 100 employees at the site · Closed Aug 17, 2004

Pulte Homes Western Skies Subdivision, Albuquerque, NM 87101 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.

Other new single-family housing construction (except for-sale builders) employers in New Mexico

Alert subscribers get notified of each newly cited employer in New Mexico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.