OSHA SearchOSHA records by employer

Pure Power Contractors, Inc.: OSHA inspections and violations

Jeffersonville, Georgia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
1citation items
$6,000current penalties
Jun 12, 2020last inspection

Pure Power Contractors, Inc. has one OSHA inspection on record in Georgia.

OSHA opened it on Jun 12, 2020 on a referral, in Jeffersonville.

From that inspection OSHA issued 1 citation item: 1 serious.

OSHA proposed $8,675 in penalties. After settlements and reviews the total is $6,000, down 31%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Pure Power Contractors, Inc. averages $6,000 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Pure Power Contractors, Inc.: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Pure Power Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344787817 OPENED JUN 12, 2020Closed

Referral · Partial · Safety · 74 employees at the site · Closed Jan 14, 2021

819 Greater New Hope Road Calvary Church Road, Jeffersonville, GA 31044 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 6, 2020: Employee suffers electrical burn from arc flash while instal

At 10:30 a.m. on June 6, 2020, Employee #1 was working for an electrical contractor. Employee #1 was connecting solar panel cables when an arc flash occurred, resulting in burns to the left hand and right forearm. Employee #1 was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.960(g)(1) · Working on or near exposed energized parts
Serious$8,675$6,000Dec 4, 2020Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 6, 2020, Jeffersonville: Hospitalization · electrocutions, electric shocks · body systems

On 6/6/2020, an employee received an electrical shock to his left hand and right forearm while performing a harness connection to a solar module. The employee was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.960 · Working on or near exposed energized parts

29 CFR 1926.960(g)(1)

(g) Protection from flames and electric arcs—(1) Hazard assessment. The employer shall assess the workplace to identify employees exposed to hazards from flames or from electric arcs.

Other electrical contractors and other wiring installation contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.