Purelight Power Newco LLC: OSHA inspections and violations

Medford, Oregon · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
8citation items
$153,989current penalties
May 30, 2024last inspection

Since 2023, OSHA inspectors have visited Purelight Power Newco LLC in Oregon 3 times.

The most recent inspection opened on May 30, 2024 after an accident, in Sublimity and is still open.

In all, OSHA issued 8 citation items: 4 serious and 4 repeat.

The proposed penalties came to $173,988; today they stand at $153,989, 11% less.

The rule cited most here is 1926.1053 (ladders in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Purelight Power Newco LLC averages $51,330 across 3 cited inspections.

Purelight Power Newco LLC: OSHA citation items per year, 2023 to 2024
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Purelight Power Newco LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347515488 OPENED MAY 30, 2024Open

Accident · Partial · Safety · 6 employees at the site · Open

18794 Silver Falls Hwy Se, Sublimity, OR 97385 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-003-1501(1)
Repeat$96,826$96,825Sep 3, 2024Final

Inspection 347468035 OPENED MAY 8, 2024Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jul 2, 2025

8024 Ajax St, White City, OR 97503 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-003-1501(1)
Repeat$13,831$13,831Jun 13, 2024Final
Citation 1, item 2
29 CFR OAR 437-003-0134(8)(A)
Repeat$13,831$13,831Jun 13, 2024Final

Inspection 346708068 OPENED MAR 22, 2023Open

Complaint · Partial · Safety · 198 employees at the site · Open

4617 Cherry Ln, Medford, OR 97501 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-003-0134(8)(A)
Serious$750$750Jul 13, 2023Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,750$3,750Jul 13, 2023Final
Citation 1, item 3
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$3,750$3,750Jul 13, 2023Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,750$3,750Jul 13, 2023Final
Citation 2, item 5
29 CFR OAR 437-003-1501(1)
Repeat$37,500$17,502Jul 13, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(5)(i)

(5)(i) Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

Other electrical contractors and other wiring installation contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.