OSHA SearchOSHA records by employer

Pyburn & Sons Building & Remodeling Inc: OSHA inspections and violations

Albany, Oregon · Residential Remodelers · NAICS 236118

3inspections
5citation items
$325current penalties
Jan 8, 2015last inspection

Since 2005, OSHA inspectors have visited Pyburn & Sons Building & Remodeling Inc in Oregon 3 times.

The most recent inspection opened on Jan 8, 2015 as a planned inspection, in Albany.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The penalties, $325 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pyburn & Sons Building & Remodeling Inc averages $100 across 1 cited inspection.

Pyburn & Sons Building & Remodeling Inc: OSHA citation items per year, 2005 to 2015
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

377employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Pyburn & Sons Building & Remodeling Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340542836 OPENED JAN 8, 2015Closed

Planned · Partial · Safety · 8 employees at the site · Closed May 26, 2015

191 Sw 34th Ave, Albany, OR 97322 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$100$100Jan 26, 2015Final

Inspection 315897538 OPENED SEP 1, 2011Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jan 30, 2012

708 3rd Ave Se, Albany, OR 97321 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$125$125Sep 30, 2011Closed
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 30, 2011Closed

Inspection 309418275 OPENED OCT 26, 2005Closed

Planned · Partial · Safety · 3 employees at the site · Closed Mar 9, 2006

Mission St & Pacific Hwy, Albany, OR 97321 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$100$100Nov 29, 2005Closed
Citation 2, item 2 Other-than-serious$0$0Nov 29, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 7020.260

Other residential remodelers employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.