OSHA SearchOSHA records by employer

Pyrotek Inc.: OSHA inspections and violations

Aurora, Ohio · Pump and Compressor Manufacturing · NAICS 333913

1inspections
5citation items
$32,962current penalties
Jul 26, 2019last inspection

OSHA inspectors have visited Pyrotek Inc. in Ohio one time.

It opened on Jul 26, 2019 on a referral, in Aurora.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The proposed penalties came to $54,936; today they stand at $32,962, 40% less.

The rule cited most here is 1910.147 (lockout/tagout), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Pyrotek Inc. averages $32,962 across 1 cited inspection.

Pyrotek Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Pyrotek Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

275employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Pyrotek Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344186135 OPENED JUL 26, 2019Closed

Referral · Partial · Safety · 6,000 employees at the site · Closed Jun 28, 2021

355 Campus Drive, Aurora, OH 44202 · Pump and Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Feb 25, 2019: Employee partially amputates finger while using band saw

At approximately 2:15 p.m. on February 25, 2019, an employee was operating a horizontal band saw. While making adjustments, the employee's finger came into contact with the moving saw blade. The left index fingertip was amputated. The employee was taken to the hospital for these injuries and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(2)(ii) · Lockout/tagout
Serious$9,472$5,683Aug 22, 2019Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$13,260$7,956Aug 22, 2019Final
Citation 1, item 3
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$9,472$5,683Aug 22, 2019Final
Citation 1, item 4
29 CFR 1910.212(a)(3)(i) · Machine guarding
Serious$13,260$7,956Aug 22, 2019Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$9,472$5,683Aug 22, 2019Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Aurora site logged 3 recordable injuries or illnesses among about 133 workers: 2.4 per 100 full-time workers, against a median of 2.1 for its industry. Those cases cost 9 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Pyrotek Aurora
Aurora · 2025
133 332.42.1

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 25, 2019, Aurora: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

On 2/25/19, an employee was operating a horizontal band saw and injured their left index finger. The employee's finger was later amputated.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(2)(ii)

(ii) If an energy isolating device is capable of being locked out, the employer's energy control program under paragraph (c)(1) of this section shall utilize lockout, unless the employer can demonstrate that the utilization of a tagout system will provide full employee protection as set forth in paragraph (c)(3) of this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.212 · Machine guarding

Other pump and compressor manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.