OSHA SearchOSHA records by employer

Quality Construction and Painting LLC: OSHA inspections and violations

Depoe Bay, Oregon · Painting and Wall Covering Contractors · NAICS 238320

1inspections
3citation items
$875current penalties
Aug 1, 2018last inspection

OSHA has inspected Quality Construction and Painting LLC once in Oregon.

The inspection began on Aug 1, 2018 as a planned inspection, in Depoe Bay.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $875 and still stand at $875.

Ladders in construction comes up most often in these citations: 2 items under 1926.1053.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Quality Construction and Painting LLC averages $875 (1 cited inspection).

Quality Construction and Painting LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

397employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Quality Construction and Painting LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343380770 OPENED AUG 1, 2018Closed

Planned · Partial · Safety · 2 employees at the site · Closed Feb 20, 2019

225 Nw Alsea Ave, Depoe Bay, OR 97341 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(a)(7) · Ladders in construction
Serious$875$875Aug 21, 2018Final
Citation 1, item 1b
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$0$0Aug 21, 2018Final
Citation 2, item 2
29 CFR OAR 437-001-0765(13)-1
Other-than-serious$0$0Aug 21, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(a)(7)

(7) Ladders shall not be tied or fastened together to provide longer sections unless they are specifically designed for such use.

29 CFR 1926.1053(b)(5)(i)

(5)(i) Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).

Other painting and wall covering contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.