OSHA SearchOSHA records by employer

Quality First Home Improvement Inc.: OSHA inspections and violations

Sparks, Nevada · Roofing Contractors · NAICS 238160

4inspections
4citation items
$3,982current penalties
Feb 19, 2025last inspection

Since 2015, OSHA inspectors have visited Quality First Home Improvement Inc. in Nevada 4 times.

The most recent inspection opened on Feb 19, 2025 on a referral, in Sparks.

In all, OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

The proposed penalties came to $6,465; today they stand at $3,982, 38% less.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Quality First Home Improvement Inc. averages $1,991 across 2 cited inspections.

Quality First Home Improvement Inc. also files yearly injury logs with OSHA, summarized below.

Quality First Home Improvement Inc.: OSHA citation items per year, 2015 to 2025
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

112employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Quality First Home Improvement Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348049594 OPENED FEB 19, 2025Closed

Referral · Partial · Safety · 2 employees at the site · Closed Aug 15, 2025

2390 Probasco Way, Sparks, NV 89431 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,965$2,482Mar 18, 2025Final

Inspection 345500789 OPENED AUG 24, 2021Closed

Referral · No inspection · Safety · Closed Aug 30, 2021

130 Carefree Dr., Sparks, NV 89431 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341141901 OPENED OCT 28, 2015Closed

Follow-up · Partial · Safety · 20 employees at the site · Closed Mar 8, 2016

4840 Mill Street, Suite 1, Reno, NV 89502 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340508886 OPENED APR 1, 2015Closed

Referral · Partial · Safety · 20 employees at the site · Closed Mar 8, 2016

10 East Sky Ranch Blvd, Sparks, NV 89441 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,200$1,200Aug 4, 2015Final
Citation 2, item 1
29 CFR NEVADA REVISED STATUTES 618.987(1
Other-than-serious$150$150Aug 4, 2015Final
Citation 2, item 2
29 CFR NEVADA REVISED STATUTES 618.987(2
Other-than-serious$150$150Aug 4, 2015Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Reno site logged 0 recordable injuries or illnesses among about 14 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Quality First Home Improvement, Inc. Reno Warehouse
Reno · 2024
14 000.01.8
Quality First Home Improvement, Inc. - Reno
Reno · 2024
17 1010.51.8

Included with any plan: 5 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other roofing contractors employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.