OSHA SearchOSHA records by employer

Quality Ironworks: OSHA inspections and violations

Dallas, Texas · Iron and Steel Pipe and Tube Manufacturing from Purchased Steel · NAICS 331210

6inspections
8citation items
$16,352current penalties
Sep 5, 2024last inspection

Since 2001, OSHA inspectors have visited Quality Ironworks in Texas 6 times.

The most recent inspection opened on Sep 5, 2024 as a planned inspection, in Bandera.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The proposed penalties came to $27,591; today they stand at $16,352, 41% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Quality Ironworks averages $3,958 across 3 cited inspections.

1 inspection on this page followed a fatal incident.

Quality Ironworks also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Quality Ironworks: OSHA citation items per year, 2001 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Quality Ironworks and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347734238 OPENED SEP 5, 2024Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jan 10, 2025

1769 Texas 173, Bandera, TX 78003 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,765$1,659Dec 5, 2024Final
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,074$1,244Dec 5, 2024Final

Inspection 344305404 OPENED SEP 11, 2019Closed

Unprogrammed other · Partial · Safety · 55 employees at the site · Closed Oct 4, 2019

13675 Noel Road, Dallas, TX 75240 · Iron and Steel Pipe and Tube Manufacturing from Purchased Steel · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343641320 OPENED DEC 4, 2018Closed

Planned · Partial · Safety · 20 employees at the site · Closed Jan 2, 2019

1651 Matilda Street, Dallas, TX 75206 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$5,174$3,104Dec 18, 2018Final

Inspection 341804946 OPENED SEP 28, 2016Closed

Referral · Partial · Safety · 190 employees at the site · Closed Feb 10, 2017

1607 W. Commerce, Dallas, TX 75208 · Iron and Steel Pipe and Tube Manufacturing from Purchased Steel · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$9,778$5,867Jan 27, 2017Final

Inspection 309542256 OPENED JAN 25, 2007Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 12, 2007

2929 Wycliff, Dallas, TX 75219 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303914030 OPENED DEC 17, 2001Closed

Accident · Complete · Safety · 39 employees at the site · Closed Apr 30, 2002

500 Singleton Blvd, Dallas, TX 75212 · OSHA's record · Phone and website on Google Maps

Incident on Dec 13, 2001 (fatal): Employee killed when struck by power press die fragment

At approximately 9:30 a.m. on December 13, 2001, Employee #1 was setting dies in a Scotchman 10-ton single throw rocking beam power press, Model Number 4010C, S erial Number 6870FF197. As the die was lowered to the plate, it shattered and a piece of the die struck the employee in the right eye, penetrating his brain. Em ergency medical services were called and the employee was transported to Parklan d Memorial Hospital. Life support was removed and Employee #1 was pronounced dea d at 10:00 p.m. on December 14, 2001.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$1,200$90Mar 22, 2002Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$3,000$2,250Mar 22, 2002Closed
Citation 1, item 3
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$1,500$562Mar 22, 2002Closed
Citation 1, item 4
29 CFR 1910.303(c) · Electrical equipment, general requirements
Serious$2,100$1,575Mar 22, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Dallas site logged 2 recordable injuries or illnesses among about 83 workers: 2.1 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Quality Ironworks Inc.
Dallas · 2024
83 202.13.6

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Sep 26, 2016, Dallas: Hospitalization · fractures · wrist(s) and arm(s), unspecified

An employee fell approximately 6 feet from a steel rack to the ground below, fracturing a wrist and arm.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1926.453 · Aerial lifts

Other iron and steel pipe and tube manufacturing from purchased steel employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.