OSHA SearchOSHA records by employer

Quality Roofing & Siding LLC: OSHA inspections and violations

Gloversville, New York · Siding Contractors · NAICS 238170

1inspections
3citation items
$4,102current penalties
Aug 3, 2021last inspection

Quality Roofing & Siding LLC has one OSHA inspection on record in New York.

OSHA opened it on Aug 3, 2021, in Gloversville.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $9,945 in penalties. After settlements and reviews the total is $4,102, down 59%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Quality Roofing & Siding LLC averages $4,102 over 1 cited inspection in that time.

Quality Roofing & Siding LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Quality Roofing & Siding LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345462725 OPENED AUG 3, 2021Closed

Programmed other · Partial · Safety · 3 employees at the site · Closed Aug 11, 2022

65 Temple Street, Gloversville, NY 12078 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$2,486$1,492Jan 20, 2022Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,351$2,611Jan 20, 2022Final
Citation 1, item 2b
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$3,108$0Jan 20, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other siding contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.