Inspection 340612662 OPENED MAY 6, 2015Closed
7209 Rutherford Road, Baltimore, MD 21244 · Machine Shops · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $1,125 | $562 | Sep 23, 2015 | Final |
| Citation 1, item 2a 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $1,575 | $1,102 | Sep 23, 2015 | Final |
| Citation 1, item 2b 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $0 | $0 | Sep 23, 2015 | Final |
| Citation 1, item 2c 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Sep 23, 2015 | Final |
| Citation 1, item 2d 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $0 | $0 | Sep 23, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $1,575 | $945 | Sep 23, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting |
Serious | $562 | $337 | Sep 23, 2015 | Final |
| Citation 1, item 5 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $675 | $405 | Sep 23, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 23, 2015 | Final |
| Citation 2, item 2 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 23, 2015 | Final |
| Citation 2, item 3 29 CFR 1910.147(c)(7)(iv) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 23, 2015 | Final |
| Citation 2, item 4 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Sep 23, 2015 | Final |
| Citation 2, item 5 29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 23, 2015 | Final |
| Citation 2, item 6 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 23, 2015 | Final |