OSHA SearchOSHA records by employer

Quest Masonry, Inc.: OSHA inspections and violations

Lone Tree, Colorado · Masonry Contractors · NAICS 238140

1inspections
6citation items
$14,000current penalties
Jul 27, 2017last inspection

Quest Masonry, Inc. has one OSHA inspection on record in Colorado.

OSHA opened it on Jul 27, 2017 on a referral, in Lone Tree.

From that inspection OSHA issued 6 citation items: 6 other-than-serious.

OSHA proposed $17,746 in penalties. After settlements and reviews the total is $14,000, down 21%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Quest Masonry, Inc. averages $14,000 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Quest Masonry, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

134employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Quest Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342501848 OPENED JUL 27, 2017Closed

Referral · Partial · Safety · 3 employees at the site · Closed Feb 22, 2018

9980 Trainstation Circle, Lone Tree, CO 80124 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 27, 2017: Two workers on scaffold's fifth level fall when planks tilt

At 9:30 a.m. on July 27, 2017, Employees #1 and #2, employed by a construction company, were performing exterior masonry work at a multiemployer construction project, a multifamily residential building. They were working from the fifth level of a scaffold and installing wire mesh. The planks that formed the scaffold's work platform tilted to one side, and both employees fell, a fall height of 40 feet. Emergency services were called, and Employees #1 and #2 were transported to the hospital. They were admitted and treated for injuries related to the fall, including a fracture of Employee #1's left arm.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(6) · Scaffolds, general requirements
Other-than-serious$8,873$7,000Oct 20, 2017Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$0$0Oct 20, 2017Final
Citation 1, item 1c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Other-than-serious$0$0Oct 20, 2017Final
Citation 1, item 1d
29 CFR 1926.452(i)(7) · Rules for each type of scaffold
Other-than-serious$0$0Oct 20, 2017Final
Citation 1, item 2a
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Other-than-serious$8,873$7,000Oct 20, 2017Final
Citation 1, item 2b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Other-than-serious$0$0Oct 20, 2017Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jul 27, 2017, Lone Tree: Hospitalization · fractures · arm(s), unspecified

Two employees were installing mesh wire from the fifth level of a scaffold. The planks tilted to one side of the scaffold and the employees fell 40 feet. They were hospitalized with a broken left arm and broken ribs.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(6)

(6) On scaffolds where scaffold planks are abutted to create a long platform, each abutted end shall rest on a separate support surface. This provision does not preclude the use of common support members, such as “T” sections, to support abutting planks, or hook on platforms designed to rest on common supports.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.