OSHA SearchOSHA records by employer

Quincy Petroleum Manufacturing: OSHA inspections and violations

Quincy, Illinois · Air and Gas Compressor Manufacturing · NAICS 333912

1inspections
3citation items
$11,770current penalties
Aug 3, 2017last inspection

OSHA has inspected Quincy Petroleum Manufacturing once in Illinois.

The inspection began on Aug 3, 2017 on a referral, in Quincy.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $18,108 and now stand at $11,770, 35% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 3 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Quincy Petroleum Manufacturing averages $11,770 (1 cited inspection).

Quincy Petroleum Manufacturing: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

421employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Quincy Petroleum Manufacturing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342530300 OPENED AUG 3, 2017Closed

Referral · Partial · Safety · 300 employees at the site · Closed Jan 18, 2018

1800 Gardner Expressway, Quincy, IL 62305 · Air and Gas Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jul 29, 2017: Employee suffers amputation of two fingertips when caught in

At 10:30 a.m. on July 29, 2017, Employee #1, an assembler, and a coworker, a tester, were troubleshooting a Water Jetting 450 Pump. After the coworker connected the hoses, he checked the clamps to ensure they were loose, and then turned on the water. Once the equipment was energized and ensured no water was leaking, the two employees checked the clamps and found that they were tight. In order for the pump to function correctly, the pumps must be loose, so it was decided that they would remove the clamps and replace them with new ones. When Employee #1 was in the process of removing the clamp, the piston rod came together and resulted in the amputation of two fingertips on his left hand.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$9,054$5,885Oct 27, 2017Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Oct 27, 2017Final
Citation 1, item 2
29 CFR 1910.147(d) · Lockout/tagout
Serious$9,054$5,885Oct 27, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

29 CFR 1910.147(d)

(d) Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: