OSHA SearchOSHA records by employer

Quiroz Plastering Inc: OSHA inspections and violations

Winter Garden, Florida · Drywall and Insulation Contractors · NAICS 238310

1inspections
5citation items
$13,135current penalties
Jun 11, 2024last inspection

Quiroz Plastering Inc has one OSHA inspection on record in Florida.

OSHA opened it on Jun 11, 2024 as a planned inspection, in Winter Garden.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $13,135 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Quiroz Plastering Inc averages $13,135 over 1 cited inspection in that time.

Quiroz Plastering Inc: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Quiroz Plastering Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347541393 OPENED JUN 11, 2024Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jun 2, 2025

2272 Western Way, Winter Garden, FL 34787 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(2) · Eye and face protection in construction
Serious$2,765$2,765Aug 30, 2024Final
Citation 1, item 2
29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements
Serious$3,457$3,457Aug 30, 2024Final
Citation 1, item 3a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,074$2,074Aug 30, 2024Final
Citation 1, item 3b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Aug 30, 2024Final
Citation 1, item 4
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$4,839$4,839Aug 30, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(2)

(2) The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(ii)

(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other drywall and insulation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.