Inspection 341392611 OPENED APR 6, 2016Closed
111 Lagrande St., Gastonia, NC 28052 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Gastonia, North Carolina · All Other Plastics Product Manufacturing · NAICS 326199
R. A. Serafini, Inc. has 7 OSHA inspections on record in North Carolina, the first in 1983.
OSHA's last visit started on Apr 6, 2016 to follow up on an earlier case, in Gastonia.
Across those inspections OSHA issued 39 citation items: 12 serious and 27 other-than-serious.
OSHA proposed $6,850 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.1200, hazard communication (6 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. R. A. Serafini, Inc. averages $900 over 1 cited inspection in that time.
North Carolina · latest 90 days of OSHA records
234employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch R. A. Serafini, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company111 Lagrande St., Gastonia, NC 28052 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
111 Lagrande St., Gastonia, NC 28052 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Serious | $450 | $450 | Oct 29, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $450 | $450 | Oct 29, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 2 29 CFR 1910.26(c)(1) · Portable metal ladders |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 3 29 CFR 1910.134(k)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 4 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 5 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 6 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 7 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 8a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 8b 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
| Citation 2, item 8c 29 CFR 1910.1200(h)(3)(iv) · Hazard communication |
Other-than-serious | $0 | $0 | Oct 29, 2015 | Final |
111 Lagrande St., Gastonia, NC 28052 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(q)(1) · Exit routes |
Other-than-serious | $0 | $0 | Dec 15, 2010 | Closed |
| Citation 1, item 2 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Dec 15, 2010 | Closed |
111 Lagrande St., Gastonia, NC 28052 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $500 | $500 | Mar 8, 2004 | Closed |
| Citation 1, item 1b 29 CFR 1910.147(c)(5)(iid) · Lockout/tagout |
Serious | $0 | $0 | Mar 8, 2004 | Closed |
| Citation 1, item 1c 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Mar 8, 2004 | Closed |
| Citation 1, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $500 | $500 | Mar 8, 2004 | Closed |
| Citation 2, item 1 29 CFR 1910.179(j)(2) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Mar 8, 2004 | Closed |
| Citation 2, item 2 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 8, 2004 | Closed |
111 Lagrande St., Gastonia, NC 28052 · OSHA's record · Phone and website on Google Maps
Incident on Apr 24, 1997: Employee's arm partially amputated in grinder
At approximately 6:00 p.m. on April 24, 1997, Employee #1, a 20-year-old materia l handler for R. A. Serafini, Inc., a plastic injection mold manufacturer, was t old by his supervisor to clean out an IMS granulator/grinder before the molds an d color were changed for a new production run. Employee #1 apparently did not en sure that the main power source for the grinder was unplugged. He opened the top of the hopper and used a wet/dry vacuum to clean out the grinder. While doing s o, he stuck his left arm through the cutter blades and was cleaning out the area below them when the machine activated and cut through his lower arm, slicing bo th bones. Employee #1 got out of the machine and was taken to a local hospital, where his arm was reattached in emergency surgery. He was hospitalized until Apr il 28, 1997.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $2,100 | $2,100 | Jun 6, 1997 | Closed |
| Citation 1, item 2 29 CFR 1910.242(b) · Hand and power tools |
Serious | $100 | $100 | Jun 6, 1997 | Closed |
| Citation 1, item 3 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $150 | $150 | Jun 6, 1997 | Closed |
| Citation 2, item 1 29 CFR 1910.106(d)(7)(iii) · Flammable liquids |
Other-than-serious | $0 | $0 | Jun 6, 1997 | Closed |
| Citation 2, item 2 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jun 6, 1997 | Closed |
| Citation 2, item 3 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jun 6, 1997 | Closed |
| Citation 2, item 4 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 6, 1997 | Closed |
| Citation 2, item 5 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 6, 1997 | Closed |
| Citation 2, item 6 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 6, 1997 | Closed |
| Citation 2, item 7 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 6, 1997 | Closed |
111 Lagrande Street, Gastonia, NC 28052 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $1,000 | $1,000 | Jan 5, 1993 | Closed |
| Citation 1, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $600 | $600 | Jan 5, 1993 | Closed |
| Citation 1, item 3 29 CFR 1910.215(a)(3) · Grinders and abrasive wheels |
Serious | $600 | $600 | Jan 5, 1993 | Closed |
| Citation 2, item 1 29 CFR 7B0302 A |
Other-than-serious | $400 | $400 | Jan 5, 1993 | Closed |
| Citation 2, item 2 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 5, 1993 | Closed |
| Citation 2, item 3 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 5, 1993 | Closed |
111 Lagrande Street, Gastonia, NC 28052 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Other-than-serious | $0 | $0 | Apr 25, 1983 | Closed |
| Citation 1, item 2 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 25, 1983 | Closed |
| Citation 1, item 3 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Apr 25, 1983 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.101(b)
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
29 CFR 1910.106(d)(7)(iii)
(iii) Open flames and smoking. Open flames and smoking shall not be permitted in flammable liquid storage areas.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.