OSHA SearchOSHA records by employer

R&L Whitman Construction, Inc.: OSHA inspections and violations

Fall River, Massachusetts · Roofing Contractors · NAICS 238160

1inspections
3citation items
$6,600current penalties
Apr 24, 2025last inspection

OSHA has inspected R&L Whitman Construction, Inc. once in Massachusetts.

The inspection began on Apr 24, 2025 as a planned inspection, in Fall River; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $20,522 and now stand at $6,600, 68% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and R&L Whitman Construction, Inc. averages $6,600 (1 cited inspection).

R&L Whitman Construction, Inc.: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

255employers cited

55 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch R&L Whitman Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348202946 OPENED APR 24, 2025Open

Planned · Partial · Safety · 15 employees at the site · Open

1883 Highland Ave., Fall River, MA 02720 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$6,620$6,600Jul 10, 2025Final
Citation 1, item 1b
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$6,620$0Jul 10, 2025Final
Citation 1, item 1c
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$7,282$0Jul 10, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.451(g)(1)(i)

(i) Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system;

Other roofing contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.