R & M Masonry Contractors Inc.: OSHA inspections and violations

Philadelphia, Pennsylvania · Masonry Contractors · NAICS 238140

5inspections
18citation items
$41,896current penalties
Apr 11, 2017last inspection

R & M Masonry Contractors Inc. has 5 OSHA inspections on record in Pennsylvania, the first in 2008.

OSHA's last visit started on Apr 11, 2017 on a referral, in Philadelphia, and the case has not closed yet.

Across those inspections OSHA issued 18 citation items: 13 serious, 2 repeat and 3 other-than-serious.

OSHA proposed $102,073 in penalties. After settlements and reviews the total is $41,896, down 59%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (13 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. R & M Masonry Contractors Inc. averages $20,496 over 1 cited inspection in that time.

R & M Masonry Contractors Inc.: OSHA citation items per year, 2008 to 2017
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

274employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch R & M Masonry Contractors Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342240298 OPENED APR 11, 2017Open

Referral · Partial · Safety · 35 employees at the site · Open

2104 Market St, Philadelphia, PA 19103 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Other-than-serious$9,760$6,832Aug 16, 2017Final
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Other-than-serious$9,760$0Aug 16, 2017Final
Citation 2, item 3a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$19,520$13,664Aug 16, 2017Final
Citation 2, item 3b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$19,520$0Aug 16, 2017Final
Citation 2, item 3c
29 CFR 1926.454(a) · Scaffold training
Serious$13,943$0Aug 16, 2017Final

Inspection 339928335 OPENED AUG 29, 2014Closed

Planned · Partial · Safety · 6 employees at the site · Closed Nov 9, 2017

410 S Front Street, Philadelphia, PA 19147 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,800$2,800Feb 19, 2015Final
Citation 1, item 1b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Feb 19, 2015Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,800$2,800Feb 19, 2015Final
Citation 1, item 3a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,800$2,800Feb 19, 2015Final
Citation 1, item 3b
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$0$0Feb 19, 2015Final

Inspection 336086988 OPENED AUG 31, 2012Closed

Unprogrammed other · Partial · Safety · 18 employees at the site · Closed Nov 9, 2012

666 Reeves Road, Warminster, PA 18974 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314233255 OPENED MAR 17, 2011Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Jul 2, 2014

N. 31st & W. Berks Streets, Philadelphia, PA 19111 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$5,390$0Jun 6, 2011Closed
Citation 2, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$10,780$8,000Jun 6, 2011Closed
Citation 2, item 1c
29 CFR 1926.454(a) · Scaffold training
Repeat$0$0Jun 6, 2011Closed

Inspection 310721253 OPENED MAY 19, 2008Closed

Referral · Partial · Safety · 9 employees at the site · Closed May 15, 2014

973 North 7th Street, Philadelphia, PA 19123 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,500$2,500Jul 1, 2008Closed
Citation 1, item 1b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Jul 1, 2008Closed
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jul 1, 2008Closed
Citation 1, item 2a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,500$2,500Jul 1, 2008Closed
Citation 1, item 2b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Jul 1, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other masonry contractors employers in Pennsylvania