OSHA SearchOSHA records by employer

R&R Service Group LLC: OSHA inspections and violations

Miami, Florida · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
2citation items
$12,062current penalties
Oct 16, 2023last inspection

R&R Service Group LLC has one OSHA inspection on record in Florida.

OSHA opened it on Oct 16, 2023 on a referral, in Miami.

From that inspection OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

OSHA proposed $12,062 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. R&R Service Group LLC averages $12,062 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

R&R Service Group LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

316employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch R&R Service Group LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347050882 OPENED OCT 16, 2023Closed

Referral · Partial · Safety · 38 employees at the site · Closed Nov 21, 2025

3810 Nw 11th Street, Miami, FL 33126 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1425(e)(2) · Keeping clear of the load
Serious$11,292$11,292Jan 29, 2024Final
Citation 2, item 1
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$770$770Apr 17, 2024Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 10, 2023, Miami: Hospitalization · fractures · leg(s), unspecified

On the fifth or sixth floor deck, an employee was supervising iron workers who were measuring to place rebar. The employee was struck by a wooden tool box that was being lifted by a tower crane. The employee then struck a wooden fence and fell approximately 50 feet to the ground. The employee sustained fractures to both legs and lacerations.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.1425 · Keeping clear of the load

29 CFR 1926.1425(e)(2)

(2) Only employees essential to the operation are permitted in the fall zone (but not directly under the load). An employee is essential to the operation if the employee is conducting one of the following operations and the employer can demonstrate it is infeasible for the employee to perform that operation from outside the fall zone: (1) Physically guide the load; (2) closely monitor and give instructions regarding the load's movement; or (3) either detach it from or initially attach it to another component or structure (such as, but not limited to, making an initial connection or installing bracing).

Other poured concrete foundation and structure contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.