OSHA SearchOSHA records by employer

R B Cook Construction LLC: OSHA inspections and violations

Brattleboro, Vermont · Residential Remodelers · NAICS 236118

3inspections
10citation items
$3,600current penalties
Aug 4, 2017last inspection

Since 2009, OSHA inspectors have visited R B Cook Construction LLC in Vermont 3 times.

The most recent inspection opened on Aug 4, 2017, in Ludlow.

In all, OSHA issued 10 citation items: 10 serious.

The proposed penalties came to $5,350; today they stand at $3,600, 33% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. R B Cook Construction LLC averages $1,600 across 1 cited inspection.

R B Cook Construction LLC: OSHA citation items per year, 2009 to 2017
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

25employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch R B Cook Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342529500 OPENED AUG 4, 2017Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Nov 10, 2026

59 Main Street, Ludlow, VT 05149 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,600$1,600Oct 25, 2017Final

Inspection 314222266 OPENED JUN 14, 2012Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 27, 2012

65 Westminster Street, Bellows Falls, VT 05101 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311482186 OPENED AUG 4, 2009Closed

Planned · Complete · Safety · 8 employees at the site · Closed Dec 9, 2009

172 Elliot St., Brattleboro, VT 05301 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(iib) · Job-site wiring
Serious$600$300Sep 10, 2009Closed
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$800Sep 10, 2009Closed
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 10, 2009Closed
Citation 1, item 2c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Sep 10, 2009Closed
Citation 1, item 2d
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Sep 10, 2009Closed
Citation 1, item 2e
29 CFR 1926.451(g)(4)(ix) · Scaffolds, general requirements
Serious$0$0Sep 10, 2009Closed
Citation 1, item 3a
29 CFR 1926.454(a) · Scaffold training
Serious$1,050$600Sep 10, 2009Closed
Citation 1, item 3b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Sep 10, 2009Closed
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$600$300Sep 10, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(iib)

(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other residential remodelers employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.