OSHA SearchOSHA records by employer

R. C. Technical Welding & Fabrication, Inc.: OSHA inspections and violations

Stafford, Texas · Metal Tank (Heavy Gauge) Manufacturing · NAICS 332420

1inspections
8citation items
$27,757current penalties
Jul 19, 2016last inspection

R. C. Technical Welding & Fabrication, Inc. has one OSHA inspection on record in Texas.

OSHA opened it on Jul 19, 2016 after a fatality or catastrophe, in Stafford.

From that inspection OSHA issued 8 citation items: 8 serious.

OSHA proposed $27,757 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.184, slings (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. R. C. Technical Welding & Fabrication, Inc. averages $27,757 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

R. C. Technical Welding & Fabrication, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch R. C. Technical Welding & Fabrication, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341635357 OPENED JUL 19, 2016Closed

Fatality or catastrophe · Partial · Safety · 11 employees at the site · Closed Oct 13, 2022

12814 Mula Ln., Stafford, TX 77477 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jul 13, 2016 (fatal): Employee dies after falling from tank dome

At 9:15 a.m. on July 13, 2016, an employee was working at a facility at which metal tanks were fabricated. He was checking on the quality and specifications of a 3.0-meter-diameter (10-foot-diameter) storage tank dome. To do so, he had to climb on it. While he was on all fours, his footing slipped. He fell backward approximately 1.5 meters (5 feet) to a concrete floor. His head struck the concrete floor. He sustained a concussion. He was hospitalized, but he died as a result of his injury.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$12,471$12,471Nov 28, 2016Final
Citation 1, item 2
29 CFR 1910.29(f)(3) · Manually propelled mobile ladder stands and scaffolds (towers)
Serious$2,423$2,423Nov 28, 2016Final
Citation 1, item 3a
29 CFR 1910.179(j)(1)(ii)(b) · Overhead and gantry cranes
Serious$3,029$3,029Nov 28, 2016Final
Citation 1, item 3b
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$0$0Nov 28, 2016Final
Citation 1, item 4 Serious$2,423$2,423Nov 28, 2016Final
Citation 1, item 5a Serious$4,988$4,988Nov 28, 2016Final
Citation 1, item 5b Serious$0$0Nov 28, 2016Final
Citation 1, item 6
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$2,423$2,423Nov 28, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(g)(1)(v)

(v) Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions.

29 CFR 1910.179(j)(1)(ii)(b)

(ii) Inspection procedure for cranes in regular service is divided into two general classifications based upon the intervals at which inspection should be performed. The intervals in turn are dependent upon the nature of the critical components of the crane and the degree of their exposure to wear, deterioration, or malfunction. The two general classifications are herein designated as “frequent” and “periodic” with respective intervals between inspections as defined below:

29 CFR 1910.184 · Slings

29 CFR 1910.184(c)(6)

(6) Slings shall be securely attached to their loads.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.29 · Manually propelled mobile ladder stands and scaffolds (towers)