OSHA SearchOSHA records by employer

R D Construction, LLC: OSHA inspections and violations

San Antonio, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
3citation items
$3,900current penalties
Apr 27, 2026last inspection

R D Construction, LLC has one OSHA inspection on record in Texas.

OSHA opened it on Apr 27, 2026 on a referral, in San Antonio, and the case has not closed yet.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $7,945 in penalties. After settlements and reviews the total is $3,900, down 51%.

Most often, OSHA cited 1926.651, excavations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. R D Construction, LLC averages $3,900 over 1 cited inspection in that time.

R D Construction, LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch R D Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348903246 OPENED APR 27, 2026Open

Referral · Partial · Safety · 11 employees at the site · Open

Corner Of Goliad Road And E. Southcross, San Antonio, TX 78223 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,270$1,200Aug 18, 2026Final
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Serious$2,270$1,200Aug 18, 2026Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$3,405$1,500Aug 18, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: