OSHA SearchOSHA records by employer

R.J. Messina, Inc.: OSHA inspections and violations

North Weymouth, Massachusetts · Water and Sewer Line and Related Structures Construction · NAICS 237110

3inspections
3citation items
$4,200current penalties
Jun 8, 2017last inspection

Since 1987, OSHA inspectors have visited R.J. Messina, Inc. in Massachusetts 3 times.

The most recent inspection opened on Jun 8, 2017 as part of a related case, in Brockton.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $8,400; today they stand at $4,200, 50% less.

The rule cited most here is 1926.651 (excavations), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. R.J. Messina, Inc. averages $4,200 across 1 cited inspection.

R.J. Messina, Inc.: OSHA citation items per year, 1987 to 2017
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

260employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch R.J. Messina, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342435542 OPENED JUN 8, 2017Closed

Unprogrammed related · Partial · Health · 5 employees at the site · Closed Jun 8, 2017

1200 West Chestnut Street, Brockton, MA 02301 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341454338 OPENED MAY 6, 2016Closed

Unprogrammed other · Partial · Safety · 25 employees at the site · Closed Jun 27, 2016

Drapper Rd., Hyde Park, MA 02136 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,800$1,400May 16, 2016Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$2,800$1,400May 16, 2016Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,800$1,400May 16, 2016Final

Inspection 101444214 OPENED MAR 26, 1987Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 26, 1987

90 Sea Street, North Weymouth, MA 02191 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other water and sewer line and related structures construction employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.