R-Tex Services, LLC: OSHA inspections and violations

Ennis, Texas · Other Heavy and Civil Engineering Construction · NAICS 237990

1inspections
3citation items
$18,108current penalties
Apr 23, 2018last inspection

OSHA inspectors have visited R-Tex Services, LLC in Texas one time.

It opened on Apr 23, 2018 on a referral, in Ennis.

In all, OSHA issued 3 citation items: 3 other-than-serious.

The penalties, $18,108 in total, stand where OSHA first set them.

The rule cited most here is 1926.352 (fire prevention), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. R-Tex Services, LLC averages $18,108 across 1 cited inspection.

R-Tex Services, LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

398employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch R-Tex Services, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343106902 OPENED APR 23, 2018Closed

Referral · Complete · Safety · 72 employees at the site · Closed Nov 19, 2018

3901 I-45 South, Ennis, TX 75119 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Incident on Apr 23, 2018: Employee's leg is broken, face is burned when cutting torch

At 12:00 p.m. on April 23, 2018, Employee #1, employed by a construction company, was engaged in demolition work at a warehouse. He was preparing to use a cutting torch when the torch's tank exploded. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for a fractured leg and burns to half his face.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.352(b) · Fire prevention
Other-than-serious$9,054$9,054Oct 5, 2018Final
Citation 1, item 1b
29 CFR 1926.352(c) · Fire prevention
Other-than-serious$0$0Oct 5, 2018Final
Citation 1, item 2
29 CFR 1926.850(e) · Preparatory operations
Other-than-serious$9,054$9,054Oct 5, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.352 · Fire prevention

29 CFR 1926.352(b)

(b) If the object to be welded, cut, or heated cannot be moved and if all the fire hazards cannot be removed, positive means shall be taken to confine the heat, sparks, and slag, and to protect the immovable fire hazards from them.

29 CFR 1926.352(c)

(c) No welding, cutting, or heating shall be done where the application of flammable paints, or the presence of other flammable compounds, or heavy dust concentrations creates a hazard.

29 CFR 1926.850 · Preparatory operations

29 CFR 1926.850(e)

(e) It shall also be determined if any type of hazardous chemicals, gases, explosives, flammable materials, or similarly dangerous substances have been used in any pipes, tanks, or other equipment on the property. When the presence of any such substances is apparent or suspected, testing and purging shall be performed and the hazard eliminated before demolition is started.

Other other heavy and civil engineering construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.