Inspection 341409910 OPENED APR 12, 2016Closed
1028 Kinau St, Honolulu, HI 96814 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2014, OSHA inspectors have visited Ral Plumbing in Hawaii 3 times.
The most recent inspection opened on Apr 12, 2016 on a referral, in Honolulu.
In all, OSHA issued 3 citation items: 3 serious.
The penalties, $1,800 in total, stand where OSHA first set them.
The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ral Plumbing averages $1,050 across 1 cited inspection.
Hawaii · latest 90 days of OSHA records
64employers cited
Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Hawaii
Checking a subcontractor, a client or your own company? Watch Ral Plumbing and get notified the morning OSHA posts a new citation for it.
Watch this company1028 Kinau St, Honolulu, HI 96814 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4162 Puu Panini Ave #a, Honolulu, HI 96816 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $1,050 | $1,050 | May 13, 2015 | Final |
4250a Sierra Dr, Honolulu, HI 96816 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Serious | $750 | $750 | Nov 24, 2014 | Final |
| Citation 1, item 1b 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $0 | $0 | Nov 24, 2014 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.403(b)(2)
(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.
29 CFR 1926.404(f)(6)
(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.
Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.