OSHA SearchOSHA records by employer

Ramon Garcia: OSHA inspections and violations

Pearland, Texas · New Housing For-Sale Builders · NAICS 236117

4inspections
6citation items
$12,696current penalties
Jun 24, 2024last inspection

OSHA has inspected Ramon Garcia 4 times in Texas since 1999.

The latest one began on Jun 24, 2024 as a planned inspection, in Crandall.

Those inspections ended with 6 citation items: 6 serious.

Penalties were first proposed at $19,626 and now stand at $12,696, 35% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Ramon Garcia averages $8,296 (1 cited inspection).

Ramon Garcia: OSHA citation items per year, 1999 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Ramon Garcia and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347577223 OPENED JUN 24, 2024Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jun 16, 2026

1933 Coleto Road, Crandall, TX 75114 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$4,148$2,489Jul 22, 2024Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$4,839$2,903Jul 22, 2024Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,839$2,903Jul 22, 2024Final

Inspection 338967193 OPENED MAR 1, 2013Closed

Planned · Partial · Safety · 2 employees at the site · Closed Mar 29, 2013

1001 Jodie, Weatherford, TX 76087 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$1,400Mar 21, 2013Final

Inspection 308593409 OPENED JUL 12, 2006Closed

Referral · No inspection · Safety · 3 employees at the site · Closed Sep 8, 2006

13 Cherry Hill, Houston, TX 77040 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301406641 OPENED DEC 21, 1999Closed

Unprogrammed other · Partial · Health · 6 employees at the site · Closed Jun 20, 2002

3040 Fm 518, Pearland, TX 77584 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$1,500May 2, 2000Closed
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,500$1,500May 2, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

Other new housing for-sale builders employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.