OSHA SearchOSHA records by employer

Ramon Perez: OSHA inspections and violations

Hialeah Gardens, Florida · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

1inspections
3citation items
$8,017current penalties
Sep 19, 2016last inspection

Ramon Perez has one OSHA inspection on record in Florida.

OSHA opened it on Sep 19, 2016 after a complaint, in Hialeah Gardens.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $8,017 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Ramon Perez averages $8,017 over 1 cited inspection in that time.

Ramon Perez: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Ramon Perez again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341781839 OPENED SEP 19, 2016Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Dec 3, 2019

15000 Nw 97th Ave, Hialeah Gardens, FL 33018 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$2,672$2,672Oct 24, 2016Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,207$3,207Oct 24, 2016Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,138$2,138Oct 24, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other other foundation, structure, and building exterior contractors employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.