Inspection 343637187 OPENED FEB 26, 2019Closed
41 Danforth Drive, Easton, PA 18043 · Machine Shops · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Easton, Pennsylvania · Precision Turned Product Manufacturing · NAICS 332721
OSHA has inspected Randolph Manufacturing, Inc. 4 times in Pennsylvania since 2005.
The latest one began on Feb 26, 2019 as a planned inspection, in Easton.
Those inspections ended with 9 citation items: 6 serious and 3 other-than-serious.
Penalties were first proposed at $4,374 and now stand at $2,287, 48% lower after settlements or reviews.
Noise comes up most often in these citations: 6 items under 1910.95.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Randolph Manufacturing, Inc. averages $1,887 (1 cited inspection).
Pennsylvania · latest 90 days of OSHA records
285employers cited
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Randolph Manufacturing, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company41 Danforth Drive, Easton, PA 18043 · Machine Shops · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4 Danforth Drive Palmer Industrial Park, Easton, PA 18045 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $2,040 | $153 | Oct 6, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $1,734 | $1,734 | Oct 6, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Oct 6, 2015 | Final |
4 Danforth Drive, Easton, PA 18045 · Precision Turned Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4 Danforth Drive, Easton, PA 18045 · Precision Turned Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(b)(1) · Noise |
Serious | $300 | $200 | Mar 15, 2005 | Closed |
| Citation 1, item 2a 29 CFR 1910.95(d)(1) · Noise |
Serious | $300 | $200 | Mar 15, 2005 | Closed |
| Citation 1, item 2b 29 CFR 1910.95(g)(1) · Noise |
Serious | $0 | $0 | Mar 15, 2005 | Closed |
| Citation 1, item 2c 29 CFR 1910.95(i)(3) · Noise |
Other-than-serious | $0 | $0 | Mar 15, 2005 | Closed |
| Citation 1, item 2d 29 CFR 1910.95(k)(1) · Noise |
Serious | $0 | $0 | Mar 15, 2005 | Closed |
| Citation 1, item 2e 29 CFR 1910.95(l)(1) · Noise |
Serious | $0 | $0 | Mar 15, 2005 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(6)(ii)
(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
29 CFR 1910.215(b)(9)
(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)
29 CFR 1910.303(b)(7)(i)
(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.