Inspection 344109335 OPENED JUN 17, 2019Closed
Fci El Reno, El Reno, OK 73036 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
Incident on May 17, 2019: Employee is shocked, burned when tool contacts power line
At 1:30 p.m. on May 17, 2019, Employee #1, employed by a plumbing contractor, was attempting to move a new underground waterline with a metal pry bar. The employee placed the pry bar into an electrical conduit containing an energized 12.5k-volt electrical power line. The employee was shocked and burned. He was transported to the hospital and admitted for treatment of electrical shock and burns to his hands and face.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.416(a)(2) · Electrical safety in construction |
Serious | $13,127 | $13,127 | Oct 17, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.651(b)(3) · Excavations |
Serious | $13,127 | $13,127 | Oct 17, 2019 | Final |
| Citation 2, item 1 29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries |
Other-than-serious | $9,377 | $9,377 | Oct 17, 2019 | Final |