OSHA SearchOSHA records by employer

Raul Barcenas: OSHA inspections and violations

Smyrna, Georgia · Masonry Contractors · NAICS 238140

1inspections
3citation items
$11,188current penalties
Feb 24, 2022last inspection

OSHA inspectors have visited Raul Barcenas in Georgia one time.

It opened on Feb 24, 2022 as a planned inspection, in Smyrna.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $11,188 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Raul Barcenas averages $11,188 across 1 cited inspection.

Raul Barcenas: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Raul Barcenas and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345800080 OPENED FEB 24, 2022Closed

Planned · Partial · Safety · 6 employees at the site · Closed Oct 1, 2024

(lot #98) 482 Stagecoach Bend, Smyrna, GA 30082 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$4,351$4,351Apr 12, 2022Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,486$2,486Apr 12, 2022Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,351$4,351Apr 12, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

Other masonry contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.