OSHA SearchOSHA records by employer

RC Otis LLC: OSHA inspections and violations

Roseburg, Oregon · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

5inspections
7citation items
$525current penalties
Jan 8, 2018last inspection

Since 2006, OSHA inspectors have visited RC Otis LLC in Oregon 5 times.

The most recent inspection opened on Jan 8, 2018 as a planned inspection.

In all, OSHA issued 7 citation items: 3 serious and 4 other-than-serious.

The proposed penalties came to $1,025; today they stand at $525, 49% less.

The rule cited most here is 1926.1053 (ladders in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. RC Otis LLC averages $0 across 2 cited inspections.

RC Otis LLC: OSHA citation items per year, 2006 to 2018
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

388employers cited

15 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch RC Otis LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342870227 OPENED JAN 8, 2018Closed

Planned · No inspection · Safety · Closed Jan 8, 2018

1550 Comstock Rd, , OR 97469 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341726388 OPENED AUG 24, 2016Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jan 3, 2017

Pineview Estates #87, Sutherlin, OR 97479 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-001-0765(1)
Other-than-serious$0$0Sep 9, 2016Final
Citation 1, item 2
29 CFR OAR 437-003-0503(2)(A)-1
Other-than-serious$0$0Sep 9, 2016Final

Inspection 341704310 OPENED AUG 17, 2016Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 3, 2017

1625 W Duke Rd, Sutherlin, OR 97479 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Sep 9, 2016Final

Inspection 313543548 OPENED AUG 12, 2009Closed

Planned · No inspection · Safety · Closed Aug 12, 2009

1407 Upper Cleveland Rapids Rd, Roseburg, OR 97471 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309690436 OPENED MAR 28, 2006Closed

Planned · Partial · Safety · 6 employees at the site · Closed Sep 15, 2006

Se Lane & Se Rose St, Roseburg, OR 97470 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7031501
Serious$375$200Apr 28, 2006Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$375$200Apr 28, 2006Final
Citation 1, item 3 Serious$275$125Apr 28, 2006Final
Citation 99, item 4 Other-than-serious$0$0Apr 28, 2006Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 7010.7650

29 CFR 7030.5030

Other new single-family housing construction (except for-sale builders) employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.