OSHA SearchOSHA records by employer

Rda Construction Services LLC: OSHA inspections and violations

Lake Park, North Carolina · Siding Contractors · NAICS 238170

1inspections
3citation items
$1,500current penalties
Jun 10, 2025last inspection

OSHA inspectors have visited Rda Construction Services LLC in North Carolina one time.

It opened on Jun 10, 2025 as a planned inspection, in Lake Park.

In all, OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

The penalties, $1,500 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Rda Construction Services LLC averages $1,500 across 1 cited inspection.

Rda Construction Services LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Rda Construction Services LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348313784 OPENED JUN 10, 2025Closed

Planned · Partial · Health · 6 employees at the site · Closed Jan 8, 2026

2009 Nettle Bank Rd (lot 3292), Lake Park, NC 28079 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$750$750Aug 5, 2025Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Aug 5, 2025Final
Citation 2, item 2
29 CFR 1926.1153(c)(1) · Silica dust in construction
Other-than-serious$750$750Aug 5, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.1153(c)(1)

(c) Specified exposure control methods. (1) For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.

Other siding contractors employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.