OSHA SearchOSHA records by employer

RE Johnson Electric Inc.: OSHA inspections and violations

Meadville, Pennsylvania · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

5inspections
3citation items
$5,249current penalties
Aug 5, 2025last inspection

OSHA has inspected RE Johnson Electric Inc. 5 times in Pennsylvania since 2003.

The latest one began on Aug 5, 2025 as a planned inspection, in Greenville.

Those inspections ended with 3 citation items: 1 serious and 2 other-than-serious.

Penalties were first proposed at $5,316 and now stand at $5,249, 1% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and RE Johnson Electric Inc. averages $5,125 (1 cited inspection).

RE Johnson Electric Inc.: OSHA citation items per year, 2003 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

287employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch RE Johnson Electric Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348417734 OPENED AUG 5, 2025Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 24, 2025

75 College Ave, Greenville, PA 16125 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Other-than-serious$3,075$3,075Aug 26, 2025Final
Citation 1, item 2
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$2,050$2,050Aug 26, 2025Final

Inspection 348262155 OPENED MAY 19, 2025Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Nov 19, 2025

15487 State Route 86, Meadville, PA 16335 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311874077 OPENED JUN 11, 2009Closed

Planned · Complete · Safety · 37 employees at the site · Closed Jun 18, 2009

Grove Street; Meadville Medical Center, Meadville, PA 16335 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311872766 OPENED JAN 26, 2009Closed

Unprogrammed other · Complete · Safety · 25 employees at the site · Closed Jan 28, 2009

Grove Street; Meadville Medical Center, Meadville, PA 16335 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306450057 OPENED JUL 22, 2003Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Sep 18, 2003

Allegheny College Henderson Campus Center 520 N. M, Meadville, PA 16335 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$191$124Sep 8, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

Other electrical contractors and other wiring installation contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.